2 Parameters
2.2 List of parameters
For this device specialization, the components of the target topology may only differ from those of the actual topology
by the serial numbers and order numbers.
Note:
p9905 is automatically set to 0 at the end of the operation.
In order to permanently accept the data, it is necessary to save in a non-volatile fashion (p0977).
p9906
Topology comparison comparison stage of all components / Topo_cmpr tot comp
CU_G130_DP,
Can be changed: C1(1)
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the type of comparison between the actual topology and target topology.
The comparison is started by setting the required value.
Value:
0:
1:
2:
3:
99:
Note:
The electronic rating plate comprises the following data:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
- manufacturer (e.g. SIEMENS)
- hardware version (e.g. "A")
- Serial No. (e.g. "T-P30050495")
When comparing the topology, the following data is compared in the target and actual topologies:
p9906 = 0: Component type, Order No., Hardware version, Manufacturer, Serial No.
p9906 = 1: Component type, Order No.
p9906 = 2: Component type
p9906 = 3: Component class (e.g. Sensor Module or Motor Module)
p9907

Topology comparison comparison stage of the component number /

Topo_cmpr comp_no
CU_G130_DP,
Can be changed: C1(1)
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0
Description:
Enters the number of the component where the setting of how the actual topology should be compared to the target
topology should be changed.
Dependency:
Refer to: p9908
p9908
Topology comparison comparison stage of a component / Topo_cmpr 1 comp
CU_G130_DP,
Can be changed: C1(1)
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the type of comparison of a component in the target topology with the actual topology.
The comparison is started by setting the required value.
Value:
0:
1:
2:
950
High: Compares the complete electronic rating plate
Average: Compares the component type and the Order number
Low: Compares the component type
Minimum: Compares the component class
Topology has different comparison stages
High: Compares the complete electronic rating plate
Average: Compares the component type and the Order number
Low: Compares the component type
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
99
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
199
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
99
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents