Co: Technology Controller Fixed Value 9 / Tec_Ctr Fix Val 9; Co: Technology Controller Fixed Value 10 / Tec_Ctr Fix Val 10; Co: Technology Controller Fixed Value 11 / Tec_Ctr Fix Val 11; Co: Technology Controller Fixed Value 12 / Tec_Ctr Fix Val 12 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p2209[0...n]

CO: Technology controller fixed value 9 / Tec_ctr fix val 9

VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the value for fixed value 9 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2210[0...n]

CO: Technology controller fixed value 10 / Tec_ctr fix val 10

VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the value for fixed value 10 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2211[0...n]

CO: Technology controller fixed value 11 / Tec_ctr fix val 11

VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the value for fixed value 11 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p2212[0...n]

CO: Technology controller fixed value 12 / Tec_ctr fix val 12

VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the value for fixed value 12 of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Units group: 9_1
Scaling: PERCENT
Max
200.00 [%]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
90.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
110.00 [%]
Access level: 2
Func. diagram: 7950
Unit selection: p0595
Expert list: 1
Factory setting
120.00 [%]