Vsm Input Line Supply Voltage Voltage Scaler / Vsm Inp U_Scaler; Co: Vsm Input Line Supply Voltage U1 - U2 / Vsm Inp U1-U2 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p3560
Vdc controller proportional gain / Vdc_ctrl Kp
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
0.01 [%]
Description:
Sets the scaled proportional gain for the DC link voltage controller (Vdc controller).
Note:
A value of 100% corresponds to the basic setting derived from the loop control parameter (p3422).
p3562
Vdc controller integral time / Vdc_ctrl Tn
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
0.10 [%]
Description:
Sets the scaled integral time for the DC link voltage controller (Vdc).
Note:
A value of 100% corresponds to the basic setting derived from the loop control parameter (p3422).
p3660[0...n]

VSM input line supply voltage voltage scaler / VSM inp U_scaler

VECTOR_G
Can be changed: T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
0.00 [%]
Description:
Sets the voltage scaler for the Voltage Sensing Module (VSM).
Note:
When the 690 V input is used (X522) without voltage scaler, 0 % should be entered.
When the 100 V input (X521) is used with voltage scaler to measure medium voltages, the dividing (scaling) factor
multiplied by 100% should be entered.
Example:
1000 V line supply voltage, voltage scaling, 10:1
--> voltage at the VSM input is 100 V
--> p3660 = 10 * 100 % = 1000 %
r3661[0...n]

CO: VSM input line supply voltage u1 - u2 / VSM inp u1-u2

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: -
Min
- [V]
Description:
Displays the input voltage between phases L1 and L2 for the Voltage Sensing Module (VSM).
Dependency:
Refer to: p3660
Note:
X521.1 or X522.1: Connection of L1
X521.2 or X522.2: Connection of L2
X521.3 or X522.3: Connection of L3
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1000.00 [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
100000.00 [%]
Calculated: -
Dyn. index: p0150
Units group: -
Scaling: PERCENT
Max
100000.00 [%]
Calculated: -
Dyn. index: p0150
Units group: 5_3
Scaling: p2001
Max
- [V]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 7960
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 2
Func. diagram: 7960
Unit selection: -
Expert list: 1
Factory setting
100.00 [%]
Access level: 3
Func. diagram: 9880
Unit selection: -
Expert list: 1
Factory setting
0.00 [%]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
571

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents