Trace 1 Trace Buffer Signal 6 / Trace 1 Tr Sig 6; Trace 1 Trace Buffer Signal 7 / Trace 1 Tr Sig 7; Trace Physical Address Signal 0 / Trace Phyaddr Sig0; Trace Physical Address Signal 1 / Trace Phyaddr Sig1 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r4776[0...16383]

Trace 1 trace buffer signal 6 / Trace 1 tr sig 6

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 6.
Dependency:
Refer to: r4760
r4777[0...16383]

Trace 1 trace buffer signal 7 / Trace 1 tr sig 7

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 7.
Dependency:
Refer to: r4760
p4780[0...1]

Trace physical address signal 0 / Trace PhyAddr Sig0

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the first signal to be traced.
The data type is defined using p4730.
Index:
[0] = Trace 0
[1] = Trace 1
p4781[0...1]

Trace physical address signal 1 / Trace PhyAddr Sig1

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0000 bin
Description:
Sets the physical address for the second signal to be traced.
The data type is defined using p4731.
Index:
[0] = Trace 0
[1] = Trace 1
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
671

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents