Par_Circuit Power Unit Temperatures Max. Depletion Layer; Co: Par_Circuit Power Unit Temperatures Max. Rectifier; Co: Par_Circuit Power Unit Temperatures Air Intake; Par_Circuit Power Unit Temperatures Electronics / Pu Temp Electr - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r7202[0...n]
Par_circuit power unit temperatures max. depletion layer / PU TempMaxDepLayer
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the maximum depletion layer temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[1].
r7203[0...n]
CO: Par_circuit power unit temperatures max. rectifier / PU temp max rect
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the maximum rectifier temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[2].
r7204[0...n]
CO: Par_circuit power unit temperatures air intake / PU temp air intake
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the air intake temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[3].
r7205[0...n]

Par_circuit power unit temperatures electronics / PU temp electr

B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the temperature of the electronics module in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[4].
r7206[0...n]
Par_circuit power unit temperatures inverter 1 / PU temp inv 1
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the inverter temperature 1 in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[5].
708
Calculated: -
Dyn. index: PDS, p0120
Units group: 21_1
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: PDS, p0120
Units group: 21_1
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: PDS, p0120
Units group: 21_1
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: PDS, p0120
Units group: 21_1
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: PDS, p0120
Units group: 21_1
Scaling: p2006
Max
- [°C]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents