Assignment Parameter 4 In Reference To P514[3] / Bicolist4_Ref4; Assignment Parameter 5 In Reference To P514[4] / Bicolist5_Ref5; Assignment Parameter 6 In Reference To P514[5] / Bicolist6_Ref6 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

The significance of the assignment parameters is as follows:
p517[0] BiCo number assigned p514[2] (reference quantity 03)
..
p517[19] BiCo number assigned p514[2] (reference quantity 03)
Dependency:
Refer to: p0514
p0518[0...19]

Assignment parameter 4 in reference to p514[3] / BiCoList4_ref4

B_INF, VECTOR_G
Can be changed: T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0
Description:
Assignment parameter for user-specific scaling.
By indexing the assignment parameter p518[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p518[0] BiCo number assigned p514[3] (reference quantity 04)
..
p518[19] BiCo number assigned p514[3] (reference quantity 04)
Dependency:
Refer to: p0514
p0519[0...19]

Assignment parameter 5 in reference to p514[4] / BiCoList5_ref5

B_INF, VECTOR_G
Can be changed: T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0
Description:
Assignment parameter for user-specific scaling.
By indexing the assignment parameter p519[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
The significance of the assignment parameters is as follows:
p519[0] BiCo number assigned p514[4] (reference quantity 05)
..
p519[19] BiCo number assigned p514[4] (reference quantity 05)
Dependency:
Refer to: p0514
p0520[0...19]

Assignment parameter 6 in reference to p514[5] / BiCoList6_ref6

B_INF, VECTOR_G
Can be changed: T
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
0
Description:
Assignment parameter for user-specific scaling.
By indexing the assignment parameter p520[0..19], a total of 20 BiCos are available, which should be scaled
corresponding to the user-specific scaling.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: CALC_MOD_ALL
Dyn. index: -
Units group: -
Scaling: -
Max
4294967295
Calculated: CALC_MOD_ALL
Dyn. index: -
Units group: -
Scaling: -
Max
4294967295
Calculated: CALC_MOD_ALL
Dyn. index: -
Units group: -
Scaling: -
Max
4294967295
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
209

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents