Field Bus Int Protocol Selection / Field Bus Protocol; Master Control Control Word Effective / Pcctrl Stw Eff - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p2030

Field bus int protocol selection / Field bus protocol

CU_G130_DP,
Can be changed: T
CU_G150_DP
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
3
Description:
Sets the communication protocol for the field bus interface.
Value:
3:
6:
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
r2032

Master control control word effective / PcCtrl STW eff

B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective control word 1 (STW1) of the drive for the master control.
Bit field:
Bit
00
01
03
07
10
Notice:
The master control only influences control word 1 and speed setpoint 1. Other control words/setpoints can be
transferred from another automation device.
Note:
OC: Operating condition
r2032
Master control control word effective / PcCtrl STW eff
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the effective control word 1 (STW1) of the drive for the master control.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
Notice:
The master control only influences control word 1 and speed setpoint 1. Other control words/setpoints can be
transferred from another automation device.
Note:
OC: Operating condition
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
PROFIBUS
USS(RS232)
Signal name
ON/OFF1
OC / OFF2
Operation enable
Acknowledge fault
Master ctrl by PLC
Signal name
ON/OFF1
OC / OFF2
OC / OFF3
Operation enable
Ramp-function generator enable
Start ramp-function generator
Speed setpoint enable
Acknowledge fault
Jog bit 0
Jog bit 1
Master ctrl by PLC
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
FP
-
-
-
-
-
FP
-
-
-
-
-
-
-
-
3030
3030
-
465

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents