Co: Can Free Pzd Receive Objects 16 Bit / Free Pzd Recv 16; Ci: Can Free Pzd Send Objects 16 Bit / Free Pzd Send 16 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Value:
1:
2:
r8745[0...15]

CO: CAN free PZD receive objects 16 bit / Free PZD recv 16

VECTOR_G (CAN)
Can be changed: -
Data type: Integer16
P-Group: -
Not for motor type: -
Min
-
Description:
Access to free PZD receive objects 16 bit using the SDO transfer.
An index can only be used, if the corresponding object has not been mapped in a PDO.
Index:
[0] = PZD object 0
[1] = PZD object 1
[2] = PZD object 2
[3] = PZD object 3
[4] = PZD object 4
[5] = PZD object 5
[6] = PZD object 6
[7] = PZD object 7
[8] = PZD object 8
[9] = PZD object 9
[10] = PZD object 10
[11] = PZD object 11
[12] = PZD object 12
[13] = PZD object 13
[14] = PZD object 14
[15] = PZD object 15
Note:
Index 0 corresponds to the CANopen object 5800 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 1 corresponds to the CANopen object 5801 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 2 corresponds to the CANopen object 5802 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 3 corresponds to the CANopen object 5803 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 4 corresponds to the CANopen object 5804 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 5 corresponds to the CANopen object 5805 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 6 corresponds to the CANopen object 5806 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 7 corresponds to the CANopen object 5807 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 8 corresponds to the CANopen object 5808 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 9 corresponds to the CANopen object 5809 hex + 80 hex * x (x: Drive number 0 ... 7).
Index 10 corresponds to the CANopen object 580A hex + 80 hex * x (x: Drive number 0 ... 7).
Index 11 corresponds to the CANopen object 580B hex + 80 hex * x (x: Drive number 0 ... 7).
Index 12 corresponds to the CANopen object 580C hex + 80 hex * x (x: Drive number 0 ... 7).
Index 13 corresponds to the CANopen object 580D hex + 80 hex * x (x: Drive number 0 ... 7).
Index 14 corresponds to the CANopen object 580E hex + 80 hex * x (x: Drive number 0 ... 7).
Index 15 corresponds to the CANopen object 580F hex + 80 hex * x (x: Drive number 0 ... 7).
p8746[0...15]

CI: CAN free PZD send objects 16 bit / Free PZD send 16

VECTOR_G (CAN)
Can be changed: U, T
Data type: Unsigned32 / Integer16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Sets the signal source for free PZD send objects 16 bit for SDO transfer.
An index can only be used, if the corresponding object has not been mapped in a PDO.
Index:
[0] = PZD object 0
[1] = PZD object 1
[2] = PZD object 2
774
Predefined Connection Set
Free PDO Mapping
Calculated: -
Dyn. index: -
Units group: -
Scaling: 4000H
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: 4000H
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0