Si Motion Sbt Control Word Diagnostics / Sbt Stw Diag; Co/Bo: Si Safety Info Channel Status Word S_Zsw3B / Sic S_Zsw3B - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
[3] = Select test torque sign
[4] = Select test sequence
[5] = External brake status
Note:
Re BI: p10230[0]:
0/1 signal: select brake test.
0 signal: inactive.
Re BI: p10230[1]:
0/1 signal: start brake test.
Re BI: p10230[2]:
1 signal: select brake 2.
0 signal: select brake 1.
Re BI: p10230[3]:
1 signal: select negative test torque.
0 signal: select positive test torque.
Re BI: p10230[4]:
1 signal: select test sequence 2.
0 signal: select test sequence 1.
Re BI: p10230[5]:
1 signal: external brake closed.
0 signal: external brake open.
r10231

SI Motion SBT control word diagnostics / SBT STW diag

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the diagnostic bits for the control word of the safe brake test
Bit field:
Bit
00
01
02
03
04
05
Dependency:
Refer to: p10203
Note:
The bits indicate the actual control signals of the control set in p10203.
r10234.0...15

CO/BO: SI Safety Info Channel status word S_ZSW3B / SIC S_ZSW3B

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Display and BICO output for status word S_ZSW3B of the safety information channel.
Bit field:
Bit
00
01
02
03
04
05
06
07
998
Signal name
Select brake test
Start brake test
Select brake
Select test torque sign
Select test sequence
External brake status
Signal name
Brake test selected
Setpoint input drive/external
Active brake
Brake test active
Brake test result
Brake test completed
External brake request
Actual load sign
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Brake 2
Negative
Test sequence 2
Closed
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Drive
Brake 2
Yes
Successful
Yes
Close
Negative
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 2836, 2837
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
Brake 1
Positive
Test sequence 1
Open
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
External
Brake 1
No
With error
No
Open
Positive
SINAMICS G130/G150
FP
-
-
-
-
-
-
FP
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents