Trace Data Type 6 Traced / Trace Rec Type 6; Trace Data Type 7 Traced / Trace Rec Type 7; Trace Data Type 8 Traced / Trace Rec Type 8; Trace Memory Bank Changeover / Trace Mem Changeov - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r4791[0...1]

Trace data type 6 traced / Trace rec type 6

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the recorded data type 6 for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
r4792[0...1]

Trace data type 7 traced / Trace rec type 7

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the recorded data type 7 for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
r4793[0...1]

Trace data type 8 traced / Trace rec type 8

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the recorded data type 8 for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
p4795

Trace memory bank changeover / Trace mem changeov

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0
Description:
Changes over the memory bank to read out the contents of the trace buffer.
Dependency:
Refer to: r4740, r4741, r4742, r4743, r4750, r4751, r4752, r4753
r4797[0...1]
Trace 0 trigger instant / Trace 0 t_trigger
CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the instant in time for fulfilling the trigger condition for trace recorder 0.
The time comprises milliseconds (index 0) and days (index 1).
674
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
500
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
SINAMICS G130/G150