Units Changeover Adapted Parameters / Unit_Chngov Par; Number Of Bico Interconnections / Bico Count; Bico Interconnections Bi/Ci Parameters / Bico Bi/Ci Par; Bico Interconnections Bo/Co Parameters / Bico Bo/Co Par - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r9451[0...29]

Units changeover adapted parameters / Unit_chngov par

B_INF, ENC,
Can be changed: -
VECTOR_G
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
r9481

Number of BICO interconnections / BICO count

B_INF, CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Commands
CU_G150_PN, ENC,
Not for motor type: -
TB30, TM150, TM31,
TM54F_MA,
Min
TM54F_SL,
-
VECTOR_G
Description:
Displays the number of BICO interconnections (signal sinks).
Dependency:
Refer to: r9482, r9483
Note:
The selected BICO interconnections should be entered into r9482 and r9483.
r9482[0...n]

BICO interconnections BI/CI parameters / BICO BI/CI par

B_INF, CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Commands
CU_G150_PN, ENC,
Not for motor type: -
TB30, TM150, TM31,
TM54F_MA,
Min
TM54F_SL,
-
VECTOR_G
Description:
Displays the signal sinks (binector/connector inputs, BI/CI parameters).
The number of BICO interconnections is displayed in r9481.
Dependency:
Refer to: r9481, r9483
Note:
The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9483[0...n]

BICO interconnections BO/CO parameters / BICO BO/CO par

B_INF, CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Commands
CU_G150_PN, ENC,
Not for motor type: -
TB30, TM150, TM31,
TM54F_MA,
Min
TM54F_SL,
-
VECTOR_G
Description:
Displays the signal sources (binector/connector outputs, BO/CO parameters).
The number of BICO interconnections is displayed in r9481.
Dependency:
Refer to: r9481, r9482
Note:
The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: r9481
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: r9481
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
865

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents