Oa Identifier / Oa Id; Oa Version / Oa Version; Oa Interface Version / Oa Interf_Vers - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
The GUID of an OA application comprises 16 characters plus 1 character major information plus 1 character, minor
information.
GUID: Globally Unique IDentifier
r4988[0...n]

OA identifier / OA ID

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the IDs of all the OA applications installed on the memory card/device memory.
r4988[0...8]: Identifier of OA application 1
r4988[9...17]: Identifier of OA applications 2, ...
Dependency:
Refer to: r4985, r4986, r4987, r4989, r4990, r4991, r4992, r4993, r4994
Notice:
If there is no OA application, then it is not possible to access an index.
r4989[0...n]

OA version / OA version

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the version of all the OA applications installed on the memory card/device memory.
r4989[0]: Version of OA application 1
r4989[1]: Version of OA application 2, ...
Dependency:
Refer to: r4985, r4986, r4987, r4988, r4990, r4991, r4992, r4993, r4994
Notice:
If there is no OA application, then it is not possible to access an index.
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
r4990[0...n]

OA interface version / OA interf_vers

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: OEM range
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the interface version of all the OA applications installed on the memory card/device memory.
r4990[0]: Interface version of OA application 1
r4990[1]: Interface version of OA applications 2, ...
Dependency:
Refer to: r4985, r4986, r4987, r4988, r4989, r4991, r4992, r4993, r4994
Notice:
If there is no OA application, then it is not possible to access an index.
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
688
Calculated: -
Dyn. index: r4986
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: r4985
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: r4985
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents