Ci: Si Safety Control Channel Control Word S_Stw3B / Scc S_Stw3B; Si Motion Sbt Test Torque Diagnostics / Sbt M_Test Diag; Si Motion Sbt Load Torque Diagnostics / Sbt M_Load Diag; Si Motion Sbt State Diagnostics / Sbt State Diag - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

14
15
Note:
SIC: Safety Info Channel
SLP: Safely-Limited Position / SE: Safe software limit switches
p10235

CI: SI Safety Control Channel control word S_STW3B / SCC S_STW3B

VECTOR_G
Can be changed: T
Data type: Unsigned32 / Integer16
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for control word S_STW3B of the Safety Control Channel.
Dependency:
This parameter is used as control word for the safe brake test only for "SBT via SCC" (p10203 = 0).
Refer to: p10203
Note:
SBT: Safe Brake Test
SCC: Safety Control Channel
r10240

SI Motion SBT test torque diagnostics / SBT M_test diag

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [Nm]
Description:
Displays the effective maximum test torque on the motor side for a safe brake test.
Dependency:
The test torque for an external brake should be converted to the load side.
Conversion factor:
- motor type = rotary and axis type = linear: (p9521 x p9520) / p9522
- otherwise: p9521 / p9522
Further, the efficiency of the mechanical system should be taken into account.
Refer to: p10210, p10220
Note:
The value remains displayed until the start of the next test sequence.
r10241

SI Motion SBT load torque diagnostics / SBT M_load diag

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
- [Nm]
Description:
Displays the load torque for a safe brake test.
When initializing the brake test, this load torque is available at the drive.
Note:
The value remains displayed until the brake test is deselected.
r10242

SI Motion SBT state diagnostics / SBT state diag

VECTOR_G
Can be changed: -
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Displays the actual state of the safe brake test.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Acceptance test SLP (SE) active
Acceptance test mode selected
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [Nm]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [Nm]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
16
2 Parameters
2.2 List of parameters
No
No
Access level: 3
Func. diagram: 2837
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 2836
Unit selection: -
Expert list: 1
Factory setting
- [Nm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
-
-
999

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents