Co: P Flux Controller Output / P Flux Ctrl Outp; Pulse Technique Current Limit / Pulse Current Lim; Pulse Technique Pattern Configuration / Puls Pattrn Config; Co: Pulse Technique Pattern Actual / Puls Pattern Act - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r1602

CO: P flux controller output / P flux ctrl outp

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [Arms]
Description:
Displays the output of the P flux controller for separately-excited synchronous motors (FEM).
p1604[0...n]

Pulse technique current limit / Pulse current lim

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, REL, FEM
Min
0.00 [Arms]
Description:
Sets the effective current limit within the pulse technique.
Note:
The saturation characteristic of the motor defines the available operating range for the pulse technique.
This operating range can be adjusted using the current limit.
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
Otherwise, the rated motor current is used as pre-assigned value.
p1605[0...n]

Pulse technique pattern configuration / Puls pattrn config

VECTOR_G (n/M)
Can be changed: U, T
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: ASM, REL, FEM
Min
1
Description:
Sets the applied pulse patterns for estimating the continuous rotor position.
Remark:
See p1750 for the activation of the pulse-pattern technique.
Value:
1:
2:
Dependency:
Refer to: p1750
Note:
When commissioning a catalog motor, the technique is automatically selected depending on the motor type being
used.
r1606

CO: Pulse technique pattern actual / Puls pattern act

VECTOR_G (n/M)
Can be changed: -
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: ASM, REL, FEM
Min
0
Description:
Displays the currently applied pulse patterns for estimating the continuous rotor position.
Value:
0:
1:
2:
Dependency:
Refer to: p1605, p1750
396
pm
ppmm
None
pm
ppmm
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
10000.00 [Arms]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
2
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: 6726, 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents