Comm Board Read Diagnostics Channel / Cb Diag_Chan Read; Comm Board Identification Data / Cb Ident Data - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
6:
255:
r8858[0...39]

COMM BOARD read diagnostics channel / CB diag_chan read

CU_G130_DP (COMM
Can be changed: -
BOARD, PROFINET
Data type: Unsigned16
CBE20),
P-Group: Communications
CU_G130_PN (COMM
Not for motor type: -
BOARD, PROFINET
CBE20),
Min
CU_G150_DP (COMM
-
BOARD, PROFINET
CBE20),
CU_G150_PN (COMM
BOARD, PROFINET
CBE20)
Description:
Displays the COMM BOARD diagnostics data.
Note:
The display depends on the COMM BOARD being used.
Example for CBE20:
r8858[0] = 4201 --> Siemens CBE20
r8858[1] = 1 --> firmware type = PROFINET device (see p8835)
r8858[2] = x --> state of cyclic communication
r8858[3] = y --> state of the IP configuration
r8858[4] = 1281 --> device ID 0501 hex = SINAMICS S120/S150
r8858[5 ... 39] --> only for internal Siemens diagnostics.
r8859[0...7]

COMM BOARD identification data / CB ident data

CU_G130_DP (COMM
Can be changed: -
BOARD, PROFINET
Data type: Unsigned16
CBE20),
P-Group: Communications
CU_G130_PN (COMM
Not for motor type: -
BOARD, PROFINET
CBE20),
Min
CU_G150_DP (COMM
-
BOARD, PROFINET
CBE20),
CU_G150_PN (COMM
BOARD, PROFINET
CBE20)
Description:
Displays the COMM BOARD identification data
Index:
[0] = Version interface structure
[1] = Version interface driver
[2] = Company (Siemens = 42)
[3] = CB type
[4] = Firmware version
[5] = Firmware date (year)
[6] = Firmware date (day/month)
[7] = Firmware patch/hot fix
Note:
Example for CBE20:
r8859[0] = 100 --> version of the interface structure V1.00
r8859[1] = 111 --> version of the interface driver V1.11
r8859[2] = 42 --> SIEMENS
r8859[3] = 0 --> CBE20
r8859[4] = 1200 --> first part, firmware version V12.00 (second part, see index 7)
r8859[5] = 2010 --> year 2010
r8859[6] = 2306 --> 23rd June
r8859[7] = 1300 --> second part, firmware version (complete version: V12.00.13.00)
798
Cyclic communications but no setpoints (stop/no clock cycle)
Cyclic communication
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents