Smi Spare Part Save Data Of All Smis / Save Smi Data; Smi Spare Part Data Backup Directory / Smi Dat_Bkup Dir - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p4692

SMI spare part save data of all SMIs / Save SMI data

CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Displays, signals
CU_G150_PN
Not for motor type: -
Min
0
Description:
Setting to back up the data of all SMIs and DQIs featured in the target topology.
Value:
0:
1:
10:
13:
16:
20:
29:
Note:
SMI: SINAMICS Sensor Module Integrated
p4692 = 10: Automatic on successful completion of backup procedure.
p4692 = 13, 16, 20, 29: Error values if the procedure could not be executed successfully.
The procedure must be repeated if the data save operation was interrupted (e.g. if the power supply voltage failed).
Help for error value = 13:
- Use a memory card with more memory space.
Help for error value = 16:
- check the DRIVE-CLiQ wiring.
Help for error value = 20:
- Use an SMI that is not blank.
Help for error value = 29:
- Check and correct the target and actual topologies for the SMIs.
- Repeat the save procedure.
p4693[0...1]

SMI spare part data backup directory / SMI dat_bkup dir

CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Displays, signals
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the directory for downloading and saving data.
Example:
The SMI has the component number 5 and the SMI data (motor/encoder data) is to be stored in subdirectory C205.
--> p4690 = 5, p4693[0] = 205, p4691 = 1
Index:
[0] = Subdirectory selection
[1] = Reserved
Dependency:
Refer to: p4691, r4694
Notice:
If p4693[0] is not equal to 0 and p4693[0] is not equal to p4690, the following applies:
- Only a number >= 200 may be selected for the subdirectory when saving.
- In the case of downloads, a selection for the subdirectory may only be made for an SMI/DQI with a component
number >= 200 (preliminary component number) (p4690 >= 200).
Note:
DQI: DRIVE-CLiQ Sensor Integrated
SMI: SINAMICS Sensor Module Integrated
Re index 0:
This index is used to select the subdirectory for saving and downloading data. The motor order number (MLFB) of the
corresponding data backup is displayed in r4694.
For p4693[0] = 0, the following applies:
The directory is determined by the setting of p4690.
654
Inactive
Save data of all SMIs and DQIs
Save all data successful
Insufficient memory space for backup
Transfer fault during data backup
Component does not contain any data
Not all components from target topology saved
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
29
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
399
List Manual (LH2), 04/2014, A5E03263479A
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents