Current Model Controller Output / I_Mod_Ctrl Outp; Current Model Magnetizing Current D Axis / I_Mod I_Mag D-Ax; Current Model Magnetizing Current Q Axis / I_Mod I_Mag Q-Ax; Co: Current Model Isq After Actual Value Tracking / I_Mod Isq Track - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r1636

Current model controller output / I_mod_ctrl outp

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [Arms]
Description:
Displays the output of the current model controller.
r1637

Current model magnetizing current d axis / I_mod I_mag d-ax

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [Arms]
Description:
Displays the magnetizing current of the current model in the d-axis.
r1638

Current model magnetizing current q axis / I_mod I_mag q-ax

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [Arms]
Description:
Displays the magnetizing current of the current model in the q-axis.
r1639

CO: Current model Isq after actual value tracking / I_mod Isq track

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [Arms]
Description:
Displays the stator current in the q axis after the current actual value tracking.
p1640[0...n]
CI: Excitation current actual value signal source / I_exc_ActVal S_src
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
-
Description:
Sets the signal source for the excitation current actual value
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 4
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 4
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 4
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
0