Speed_Ctrl_Opt Vibration Test Number Of Periods Determined; Rotating Measurement Encoder Test Pulse Number Determined; Speed_Ctrl_Opt Saturation Characteristic Rotor Flux Maximum; Bo: Speed_Ctrl_Opt Status / N_Opt Status - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r1972[0...1]
Speed_ctrl_opt vibration test number of periods determined / n_opt per_qty det
VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor identification
Not for motor type: REL
Min
-
Description:
Displays the period number determined by the vibration test.
Index:
[0] = No. of periods of the low frequency
[1] = No. of periods of the high frequency
Dependency:
Refer to: p1959
r1973
Rotating measurement encoder test pulse number determined / n_opt puls no. det
VECTOR_G (n/M)
Can be changed: -
Data type: Integer32
P-Group: Motor identification
Not for motor type: REL
Min
-
Description:
Displays the number of pulses determined during the vibration test.
Note:
A negative signal indicates an incorrect polarity of the encoder signal.
p1974
Speed_ctrl_opt saturation characteristic rotor flux maximum / n_opt rot_fl max
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Motor identification
Not for motor type: PEM, REL, FEM
Min
104 [%]
Description:
Sets the maximum flux setpoint to measure the saturation characteristic.
r1979.0...12

BO: Speed_ctrl_opt status / n_opt status

VECTOR_G (n/M)
Can be changed: -
Data type: Unsigned16
P-Group: Motor identification
Not for motor type: REL
Min
-
Description:
Displays the status to check and monitor the states of speed controller optimization.
Bit field:
Bit
00
01
02
04
05
06
07
08
09
10
11
12
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Speed controller optimization activated
Speed controller optimization completed
Speed controller optimization interrupted
Encoder test active
Saturation char. identification active
Moment of inertia identification active
Recalc. speed controller parameters active
Speed controller vibration test active
Magnetizing inductance adapt. active
Operation with encoder after encoderless
operation
q-leakage inductance identification
Moment of inertia estimator inhibited
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: CALC_MOD_ALL
Dyn. index: -
Units group: -
Scaling: -
Max
120 [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
120 [%]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
no
FP
-
-
-
-
-
-
-
-
-
-
-
-
455

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents