Siemens SINAMICS G150 Manual page 119

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

5 = Synchronous motor separately-excited
7 = SIEMOSYN motor
8 = Reluctance motor (for textile applications)
The type information must be entered to filter motor-specific parameters and to optimize the operating characteristics
and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
Value:
0:
1:
2:
7:
8:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
100:
102:
104:
107:
108:
111:
134:
136:
166:
222:
264:
283:
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency:
Motors, selection 206, 236, 237 cannot be operated (also not as motor with DRIVE-CLiQ).
p0300 = 5 cannot be selected with SINAMICS G.
When the motor type is changed, the code number in p0301 may be reset to 0.
p0300 = 12 can only be selected for p0100 = 1 (NEMA).
When selecting a motor type from the 1LA5 and 1LA7 series, parameters p0335, p0626, p0627 and p0628 of the
thermal motor model are pre-assigned as a function of p0307 and p0311.
When selecting a 1FW4 motor, if the motor database permits this, when exiting commissioning then p1750.5 is
automatically set. This is the reason that after exiting commissioning, all parameters must be saved and a warm
restart must be initiated (e.g. p0009 = 30, p0976 = 3).
Refer to: p0301
Caution:
A permanent-magnet synchronous motor cannot be operated with an SSI encoder without HTL/TTL track.
A separately-excited synchronous motor can only be operated with an SSI encoder if this is used as the second
encoder and an HTL/TTL encoder is used as the first encoder.
Notice:
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parameters
that are associated with this list cannot be changed (write protection). The write protection is canceled if the motor
type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx). Write protection is
automatically canceled when the results of motor data identification are copied to the motor parameters.
The motor type of a catalog motor corresponds to the upper three digits of the code number or the following
assignment (if the particular motor type is listed):
Type/code number ranges
100 / 100xx, 110xx, 120xx, 130xx, 140xx, 150xx
102 / 102xx, 112xx, 122xx
104 / 104xx, 114xx, 124xx
107 / 107xx, 117xx, 127xx
108 / 108xx, 118xx, 128xx, 138xx, 148xx, 158xx
134 / 134xx, 144xx, 154xx
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
No motor
Induction motor
Synchronous motor
SIEMOSYN synchronous motor
Reluctance motor textile
1LE1 induction motor
1LA1 induction motor
1LE2 induction motor
1LG6 induction motor
1xx1 SIMOTICS FD induction motor
1LA5 induction motor
1LA6 induction motor
1LA7 induction motor
1xx8 SIMOTICS TN induction motor
1LA9 induction motor
1LE1 induction motor
1PH2 induction motor
1PH4 induction motor
1PH7 induction motor
1PH8 induction motor
xxxx induction motor OEM
1PM4 induction motor
1PM6 induction motor
1PL6 induction motor
xxxx synchronous motor OEM
1FW4 synchronous motor
1FW3 synchronous motor
2 Parameters
2.2 List of parameters
119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents