Ci: Main Setpoint / Main Setpoint; Ci: Main Setpoint Scaling / Main Setp Scal; Co: Main Setpoint Effective / Main Setpoint Eff; Ci: Supplementary Setpoint / Suppl Setp - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p1070[0...n]

CI: Main setpoint / Main setpoint

VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for the main setpoint.
Examples:
r1024: Fixed speed setpoint effective
r1050: Motor. potentiometer setpoint after the ramp-function generator
Dependency:
Refer to: p1071, r1073, r1078
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1071[0...n]

CI: Main setpoint scaling / Main setp scal

VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for scaling the main setpoint.
r1073

CO: Main setpoint effective / Main setpoint eff

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
- [rpm]
Description:
Displays the effective main setpoint.
The value shown is the main setpoint after scaling.
p1075[0...n]

CI: Supplementary setpoint / Suppl setp

VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for the supplementary setpoint.
Dependency:
Refer to: p1076, r1077, r1078
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Sets the signal source for scaling the supplementary setpoint.
296
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: p2000
Max
-
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 3001, 3030
Unit selection: -
Expert list: 1
Factory setting
1024[0]
Access level: 3
Func. diagram: 3001, 3030
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: 3030
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 3001, 3030
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 3001, 3030
Unit selection: -
Expert list: 1
Factory setting
1
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents