Friction Characteristic Value N4 / Friction N4; Friction Characteristic Value N5 / Friction N5; Friction Characteristic Value N6 / Friction N6; Friction Characteristic Value N7 / Friction N7 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p3824[0...n]

Friction characteristic value n4 / Friction n4

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 5th value pair of the friction characteristic.
Dependency:
Refer to: p3834, p3845
p3825[0...n]

Friction characteristic value n5 / Friction n5

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 6th value pair of the friction characteristic.
Dependency:
Refer to: p3835, p3845
p3826[0...n]

Friction characteristic value n6 / Friction n6

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 7th value pair of the friction characteristic.
Dependency:
Refer to: p3836, p3845
p3827[0...n]

Friction characteristic value n7 / Friction n7

VECTOR_G (n/M)
Can be changed: T
Data type: FloatingPoint32
P-Group: Functions
Not for motor type: REL
Min
0.00 [rpm]
Description:
The friction characteristic is defined by 10 value pairs.
This parameter specifies the n coordinate of the 8th value pair of the friction characteristic.
Dependency:
Refer to: p3837, p3845
582
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.00 [rpm]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
150.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
300.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
600.00 [rpm]
Access level: 2
Func. diagram: 7010
Unit selection: p0505
Expert list: 1
Factory setting
1200.00 [rpm]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents