Function Generator Status / Fg Status; Bo: Function Generator Status Signal / Fg Status Signal; Function Generator Mode / Fg Operating Mode - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r4805

Function generator status / FG status

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0
Description:
Displays the actual status of the function generator.
Value:
0:
1:
2:
3:
4:
5:
6:
Dependency:
Refer to: p4800, p4819
r4806.0

BO: Function generator status signal / FG status signal

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the status of the function generator.
0 signal: Function generator inactive
1 signal: Function generator running
Bit field:
Bit
00
p4810

Function generator mode / FG operating mode

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the operating mode of the function generator.
Value:
0:
1:
2:
3:
4:
5:
6:
99:
676
Inactive
Generate accelerating ramp to offset
Generate parameterized signal shape
Generate braking ramp
Function generator stopped due to missing enable signals
Function generator waits for BI: p4819
Function generator parameterization has been checked
Signal name
Bit 0
Connection at connector output r4818
Connection at current setpoint after filter and r4818
Connection as disturbing torque and r4818
Connection at speed setpoint after filter and r4818
Connection at current setpoint before filter and r4818
Connection at speed setpoint before filter and r4818
Connection for free measurement function r4818 and r4834
Connection at physical address and r4818
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
99
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
0 signal
OFF
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
SINAMICS G130/G150