2 Parameters
2.2 List of parameters
Displays the relative error of the current inversion(id(psid, iq) - id) / p2950:
idx4: error with respect to direct axis current for iq = 0
idx5: error with respect to direct axis current for iq = 0.5 * p2950
idx6: error with respect to direct axis current for iq = p2950
Index:
[0] = d-current
[1] = d-flux iq0
[2] = d-flux iq1
[3] = d-flux iq2
[4] = d-current error iq0
[5] = d-current error iq1
[6] = d-current error q2
Note:
The display is only generated when the pulses are inhibited.
p3100

RTC time stamp mode / RTC t_stamp mode

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
p3100 = 2: Time stamp, operating hours + 01.01.2000
Notice:
The realtime format (p3100 = 1), once selected, remains until the next time that the system is switched off. Switching
back to operating hours (p3100 = 0) or operating hours + 01.01.2000 (p3100=2) is prevented.
Note:
RTC: Real-time clock
UTC: Universal Time Coordinates
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
p3101[0...1]

RTC set UTC time / RTC set UTC

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0
Description:
Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master.
To start p3101[1] must be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
p3101[0]: Milliseconds
p3101[1]: Days
r3102[0...1]

RTC read UTC time / RTC read UTC

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the actual UTC time in the drive system.
p3102[0]: Milliseconds
p3102[1]: Days
552
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
4294967295
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150