Co/Bo: Si Tm54F Status / Si Stat; Si Tm54F Password Input / Si Password Inp; Si Tm54F Password New / Si Password New; Si Tm54F Password Acknowledgement / Si Ackn Password - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r10056.0

CO/BO: SI TM54F status / SI stat

TM54F_MA
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Display and BICO output for the status of the Terminal Module 54F (TM54F).
Bit field:
Bit
00
p10061

SI TM54F password input / SI password inp

TM54F_MA,
Can be changed: U, T
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Enters the Safety Integrated password for the Terminal Module 54F (TM54F).
This password is required to change the safety-relevant parameters.
p10062

SI TM54F password new / SI password new

TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Enters the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p10063
p10063

SI TM54F password acknowledgement / SI ackn password

TM54F_MA,
Can be changed: C2(95)
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Acknowledgement of the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency:
Refer to: p10062
Note:
The new password entered into p10062 must be re-entered in order to acknowledge.
p10062 = p10063 = 0 is automatically set after the new Safety Integrated password has been successfully
acknowledged.
992
Signal name
Test stop status
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Active
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Inactive
Access level: 3
Func. diagram: 2847
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 2847
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 2847
Unit selection: -
Expert list: 1
Factory setting
0000 hex
SINAMICS G130/G150
FP
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents