2 Parameters
2.2 List of parameters
r4834[0...4]
CO: Function generator free measurement output signal / FG fr MeasFct outp
CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
- [%]
Description:
Displays the output signal for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Dependency:
Refer to: p4810
Note:
The signals are only output in the "free measurement function" operating mode (p4810 = 6)
p4835[0...4]
Function generator free measurement function scaling / FG fr MeasFct scal
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-200.00000 [%]
Description:
Sets the scaling of the output signals for the free measurement function.
Index:
[0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Note:
The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
p4840[0...1]

MTrace cycle number setting / Cycle number

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the number of cycles of a multiple trace.
The multiple trace is de-activated with a value = 0.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4841, p4844
Notice:
A multiple trace can have a negative impact on the total system performance.
From their inherent principle of operation, flash memory cards are subject to wear as a result of write operations. As
a consequence, the lifetime of flash memory cards is reduced when using the multiple trace functionality.
682
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
200.00000 [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
4294967295
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents