2 Parameters
2.2 List of parameters
p2189[0...n]
Load monitoring torque threshold 3 upper / M_thresh 3 upper
VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2189 > p2190
Refer to: p2184, p2190
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2190[0...n]
Load monitoring torque threshold 3 lower / M_thresh 3 lower
VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2190 < p2189
Refer to: p2184, p2189
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2192[0...n]
Load monitoring delay time / Load monit t_del
VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [s]
Description:
Sets the delay time to evaluate the load monitoring.
p2194[0...n]
Torque threshold value 2 / M_thresh val 2
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [%]
Description:
Sets the torque threshold value for the message "Torque utilization < torque threshold value 2" (BO: r2199.11).
The message "torque setpoint < p2174" (BO: r2198.10) and "torque utilization < p2194" (BO: r2199.11) are only
evaluated after the run-up and the delay time has expired.
Dependency:
Refer to: r0033, p2195, r2199
524
Calculated: -
Dyn. index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
65.00 [s]
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
100.00 [%]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 8013
Unit selection: p0505
Expert list: 1
Factory setting
10000000.00 [Nm]
Access level: 3
Func. diagram: 8013
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]
Access level: 3
Func. diagram: 8013
Unit selection: -
Expert list: 1
Factory setting
10.00 [s]
Access level: 2
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
90.00 [%]
SINAMICS G130/G150