Co/Bo: Motor Holding Brake Status Word / Brake Zsw; Bi: Armature Short-Circuit / Dc Braking Activation / Asc/Dcbrk Act; Armature Short-Circuit / Dc Braking Configuration / Asc/Dcbrk Config - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r1229.1...11

CO/BO: Motor holding brake status word / Brake ZSW

VECTOR_G (Ext
Can be changed: -
brake)
Data type: Unsigned32
P-Group: Functions
Not for motor type: -
Min
-
Description:
Displays the status word for the motor holding brake.
Bit field:
Bit
01
03
04
05
06
07
08
09
10
11
p1230[0...n]

BI: Armature short-circuit / DC braking activation / ASC/DCBRK act

VECTOR_G
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Functions
Not for motor type: -
Min
-
Description:
Sets the signal source to activate the armature short-circuit or DC braking.
Dependency:
Refer to: p1231, p1232, p1233, p1234, p1235, p1236, p1237, r1238, r1239, p1345, p1346
Note:
1 signal: Armature short-circuit/DC braking activated.
0 signal: Armature short-circuit/DC braking de-activated.
p1231[0...n]

Armature short-circuit / DC braking configuration / ASC/DCBRK config

VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Functions
Not for motor type: -
Min
0
Description:
Setting to activate the various types for armature short-circuit / DC braking.
Value:
0:
1:
2:
3:
4:
5:
14:
Dependency:
Refer to: p0300, p1230, p1232, p1233, p1234, p1235, p1236, p1237, r1238, r1239, p1345, p1346
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Command open brake (continuous signal)
Pulse enable extended brake control
Brake does not open
Brake does not close
Brake threshold exceeded
Brake threshold undershot
Brake monitoring time expired
Pulse enable request missing/n_ctrl
inhibited
Brake OR logic operation result
Brake AND logic operation result
No function
External armature short-circuit with contactor feedback signal
Ext. armature short circuit without contactor feedback signal
Internal voltage protection
Internal armature short-circuit / DC braking
DC braking for OFF1/OFF3
DC braking below starting speed
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
14
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
Access level: 1
Func. diagram: 7014, 7016,
7017
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 7014, 7016,
7017
Unit selection: -
Expert list: 1
Factory setting
0
FP
2711
2711
2711
2711
2707
2704
2704
2707
2707
2707
327

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents