r0296

DC link voltage undervoltage threshold / Vdc U_lower_thresh

B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
Threshold to detect a DC link undervoltage.
If the DC link voltage falls below this threshold, the drive unit is tripped due to a DC link undervoltage condition.
Note:
The value depends on the device type and the selected device rated voltage (p0210).
r0296
DC link voltage undervoltage threshold / Vdc U_lower_thresh
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
Threshold to detect a DC link undervoltage.
If the DC link voltage falls below this threshold, the drive unit is tripped due to a DC link undervoltage condition.
Dependency:
Refer to: p0278
Note:
The value depends on the device type and the selected device rated voltage (p0210).
For booksize drive units, the following applies:
The undervoltage threshold can be reduced with p0278.
r0297

DC link voltage overvoltage threshold / Vdc U_upper_thresh

B_INF, VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
- [V]
Description:
Threshold to detect a DC link overvoltage.
If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link overvoltage.
p0300[0...n]

Motor type selection / Mot type sel

VECTOR_G
Can be changed: C2(1, 3)
Data type: Integer16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Selects the motor type or starts to read in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000 or
10001, if there is a second data set).
For p0300 < 10000 the following applies:
The first digit of the parameter value always defines the general motor type and corresponds to the third-party motor
belonging to a motor list:
1 = Rotating induction motor
2 = Rotating synchronous motor
3 = Linear induction motor (reserved)
4 = Linear synchronous motor
118
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
- [V]
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
10001
List Manual (LH2), 04/2014, A5E03263479A
Access level: 2
Func. diagram: 8750, 8760,
8850, 8864, 8950, 8964
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 2
Func. diagram: 8750, 8760,
8850, 8864, 8950, 8964
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 1
Func. diagram: 6310
Unit selection: -
Expert list: 1
Factory setting
0