Maximum Output Voltage / U_Output Max; Co: Output Voltage / U_Output; Maximum Modulation Depth / Modulat_Depth Max - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r0070
CO: Actual DC link voltage / Vdc act val
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Display and connector output for the measured actual value of the DC link voltage.
Dependency:
Refer to: r0026
Notice:
For SINAMICS S120 AC Drive (AC/AC) the following applies:
When measuring a DC link voltage < 200 V, for the Power Module (e.g. PM340) a valid measured value is not
supplied. In this case, when an external 24V power supply is connected, a value of approx. 24 V is displayed.
Note:
The DC link voltage is available smoothed (r0026) and unsmoothed (r0070).
r0071

Maximum output voltage / U_output max

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Vrms]
Description:
Displays the maximum output voltage.
Dependency:
The maximum output voltage depends on the actual DC link voltage (r0070) and the maximum modulation depth
(p1803).
Note:
As the (driven) motor load increases, the maximum output voltage drops as a result of the reduction in DC link
voltage.
r0072

CO: Output voltage / U_output

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Vrms]
Description:
Display and connector output for the actual output voltage of the power unit (Motor Module).
Dependency:
Refer to: r0025
Note:
The output voltage is available smoothed (r0025) and unsmoothed (r0072).
r0073

Maximum modulation depth / Modulat_depth max

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Modulation
Not for motor type: -
Min
- [%]
Description:
Displays the maximum modulation depth.
Dependency:
Refer to: p1803
64
Calculated: -
Dyn. index: -
Units group: 5_2
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: -
Units group: 5_1
Scaling: p2001
Max
- [Vrms]
Calculated: -
Dyn. index: -
Units group: 5_1
Scaling: p2001
Max
- [Vrms]
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 6723, 6724,
6730, 6731, 6799
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: 6301, 6640,
6700, 6722, 6723, 6724, 6725,
6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Vrms]
Access level: 3
Func. diagram: 5700, 5730,
6730, 6731, 6799
Unit selection: p0505
Expert list: 1
Factory setting
- [Vrms]
Access level: 3
Func. diagram: 6723, 6724,
6725
Unit selection: -
Expert list: 1
Factory setting
- [%]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents