Function Generator Time Slice Cycle / Fg Time Slice; Function Generator Amplitude Scaling / Fg Amplitude Scal; Function Generator Offset Scaling / Fg Offset Scal - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p4830

Function generator time slice cycle / FG time slice

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0.03125 [ms]
Description:
Sets the time slice cycle in which the function generator is called.
p4831

Function generator amplitude scaling / FG amplitude scal

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0.00000 [%]
Description:
Sets the scaling for the amplitude of the signal waveforms for all output channels.
The value can be changed while the function generator is running.
p4832[0...2]
Function generator amplitude scaling / FG amplitude scal
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-340.28235E36 [%]
Description:
Sets the scaling for the amplitude of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
p4833[0...2]

Function generator offset scaling / FG offset scal

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-340.28235E36 [%]
Description:
Sets the scaling for the offset of the signal waveforms separately for each output channel.
The value cannot be changed while the function generator is running.
Index:
[0] = First drive for connection
[1] = Second drive for connection
[2] = Third drive for connection
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
2.00000 [ms]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
200.00000 [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
340.28235E36 [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
340.28235E36 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0.12500 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
100.00000 [%]
681

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents