Modulation Depth Smoothed / Mod_Depth Smth; Current Actual Value Field-Generating Smoothed / Id_Act Smooth - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r0027
CO: Absolute actual current smoothed / I_act abs val smth
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Arms]
Description:
Displays the smoothed absolute actual current value.
Dependency:
Refer to: r0068
Notice:
This smoothed signal is not suitable for diagnostics or evaluation of dynamic operations. In this case, the
unsmoothed value should be used.
Note:
A_INF, S_INF, VECTOR: Smoothing time constant = 300 ms
SERVO: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
r0028

Modulation depth smoothed / Mod_depth smth

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [%]
Description:
Displays the smoothed actual value of the modulation depth.
Dependency:
Refer to: r0074
Note:
A_INF: Smoothing time constant = 300 ms
SERVO, VECTOR: Smoothing time constant = 100 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The modulation depth is available smoothed (r0028) and unsmoothed (r0074).
r0029

Current actual value field-generating smoothed / Id_act smooth

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [Arms]
Description:
Displays the smoothed field-generating actual current.
Dependency:
Refer to: r0076
Note:
SERVO: Smoothing time constant = 100 ms
VECTOR: Smoothing time constant = 300 ms
The signal is not suitable as a process quantity and may only be used as a display quantity.
The field-generating current actual value is available smoothed (r0029) and unsmoothed (r0076).
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2002
Max
- [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2002
Max
- [Arms]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 5730, 6799,
8850, 8950
Unit selection: -
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: 5730, 6799,
8950
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 5730, 6799
Unit selection: -
Expert list: 1
Factory setting
- [Arms]
49