p1780[0...n]
p1784[0...n]
p1785[0...n]
p1786[0...n]
r1787[0...n]
p1795[0...n]
r1797[0...n]
p1798[0...n]
p1800[0...n]
p1802[0...n]
p1803[0...n]
p1804[0...n]
p1806[0...n]
p1811[0...n]
p1820[0...n]
p1821[0...n]
p1840[0...n]
p1845[0...n]
p1846[0...n]
p1959[0...n]
p2140[0...n]
p2141[0...n]
p2142[0...n]
p2149[0...n]
p2150[0...n]
p2153[0...n]
p2155[0...n]
p2156[0...n]
p2161[0...n]
p2162[0...n]
p2163[0...n]
p2164[0...n]
p2166[0...n]
p2167[0...n]
p2174[0...n]
p2175[0...n]
p2177[0...n]
p2178[0...n]
p2181[0...n]
p2182[0...n]
p2183[0...n]
p2184[0...n]
p2185[0...n]
p2186[0...n]
p2187[0...n]
p2188[0...n]
p2189[0...n]
p2190[0...n]
p2192[0...n]
p2194[0...n]
p2195[0...n]
p2196[0...n]
p2201[0...n]
p2202[0...n]
p2203[0...n]
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Motor model adaptation configuration / MotMod adapt conf
Motor model feedback scaling / MotMod fdbk scal
Motor model Lh adaptation Kp / MotMod Lh Kp
Motor model Lh adaptation integral time / MotMod Lh Tn
Motor model Lh adaptation corrective value / MotMod Lh corr
Motor model kT adaptation integral time / MotMod kT Tn
Motor model kT adaptation corrective value / MotMod kT corr
Motor model pulse technique speed adaptation Kp / MotMod PulsTech Kp
Pulse frequency setpoint / Pulse freq setp
Modulator mode / Modulator mode
Maximum modulation depth / Modulat depth max
Filter time constant smoothed modulation index / T_filt mod_idxSmth
Filter time constant Vdc correction / T_filt Vdc_corr
Pulse frequency wobbulation amplitude / Puls wobb ampl
Reverse the output phase sequence / Outp_ph_seq rev
Dir of rot / Dir of rot
Actual value correction configuration / ActVal_corr conf
Actual value correction evaluation factor Lsig / ActVal_cor ev Lsig
Actual value correction damping factor / ActV_corr D_factor
Rotating measurement configuration / Rot meas config
Hysteresis speed 2 / n_hysteresis 2
Speed threshold 1 / n_thresh val 1
Hysteresis speed 1 / n_hysteresis 1
Monitoring configuration / Monit config
Hysteresis speed 3 / n_hysteresis 3
Speed actual value filter time constant / n_act_filt T
Speed threshold 2 / n_thresh val 2
On delay comparison value reached / t_on cmpr val rchd
Speed threshold 3 / n_thresh val 3
Hysteresis speed n_act > n_max / Hyst n_act>n_max
Speed threshold 4 / n_thresh val 4
Hysteresis speed 4 / n_hysteresis 4
Off delay n_act = n_set / t_del_off n_i=n_so
Switch-on delay n_act = n_set / t_on n_act=n_set
Torque threshold value 1 / M_thresh val 1
Motor blocked speed threshold / Mot lock n_thresh
Motor blocked delay time / Mot lock t_del
Motor stalled delay time / Mot stall t_del
Load monitoring response / Load monit resp
Load monitoring speed threshold value 1 / n_thresh 1
Load monitoring speed threshold value 2 / n_thresh 2
Load monitoring speed threshold value 3 / n_thresh 3
Load monitoring torque threshold 1 upper / M_thresh 1 upper
Load monitoring torque threshold 1 lower / M_thresh 1 lower
Load monitoring torque threshold 2 upper / M_thresh 2 upper
Load monitoring torque threshold 2 lower / M_thresh 2 lower
Load monitoring torque threshold 3 upper / M_thresh 3 upper
Load monitoring torque threshold 3 lower / M_thresh 3 lower
Load monitoring delay time / Load monit t_del
Torque threshold value 2 / M_thresh val 2
Torque utilization switch-off delay / M_util t_off
Torque utilization scaling / M_util scal
CO: Technology controller fixed value 1 / Tec_ctrl fix val1
CO: Technology controller fixed value 2 / Tec_ctr fix val 2
CO: Technology controller fixed value 3 / Tec_ctr fix val 3
2 Parameters