Faults Without Automatic Restart / F W/Out Auto Ar; Bi: Ar Connection Following Drive Object / Ar Connection Do - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
Note:
Re bit 00 ... 09:
Used to control internal sequences during the flying restart.
Depending on the motor type (p0300), the number of active bits differs.
Re bits 10 ... 17:
Are used to monitor the flying restart sequence.
p1206[0...9]

Faults without automatic restart / F w/out auto AR

B_INF, VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Functions
Not for motor type: -
Min
0
Description:
Sets faults for which automatic restart should not be effective.
Dependency:
The setting is only effective for p1210 = 6, 16.
Refer to: p1210
p1207

BI: AR connection following drive object / AR connection DO

B_INF
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Functions
Not for motor type: -
Min
-
Description:
Modifies the pre-charging monitoring of the infeed.
The active automatic restart (AR) of the following drive object can be interconnected using this binector input (BI:
p1207 = r1214.2).
This means that when the automatic restart is operational, the pre-charging monitoring of the infeed is de-activated
and is only re-activated under the following conditions:
- the absolute current in the DC link is greater than 2 % of the maximum current (r0209) of the infeed to provide
protection against short-circuit in the DC link.
- if a Voltage Sensing Module (VSM) is being used, the line supply voltage amplitude is greater than 3 % of the
parameterized unit supply voltage (p0210) to protect the pre-charging resistors against continuous filter current when
the line supply partially returns.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Speed adaptation circuit record angle
Speed adaptation circuit set gain to 0
Isd channel enable
Speed control switched out
Quadrature arm switched in
Special transformation active
Speed adaptation circuit set I comp to 0
Current control on
Isd_set = 0 A
Frequency held
Search in the positive direction
Search Started
Current impressed
Search interrupted
Speed adaptation circuit deviation = 0
Speed control activated
Fast flying restart w/ voltage model for
induction motor activ.
Fast flying restart w/ voltage model for
induction motor exited
Apply VSM voltage to the monitor
Preassign flux ramp
Adaptation current controller and speed
adapt. controller gain
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
315

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents