This parameter specifies the speed (n) of point 5 as a [%].
Dependency:
Refer to: r0041, p3320, p3321, p3322, p3323, p3324, p3325, p3326, p3327, p3328
Note:
The reference value for power and speed is the rated power/rated speed.
The energy saved is displayed in r0041.
r3402
Infeed status internal BIC / INF state int
B_INF
Can be changed: -
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: -
Min
0
Description:
Displays the internal status of the infeed module.
Value:
0:
1:
2:
3:
4:
5:
6:
r3405.7
CO/BO: Infeed status word / Inf ZSW
B_INF
Can be changed: -
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Display and connector output for the status word of the infeed.
Bit field:
Bit
07
r3405.1...8
CO/BO: Status word DC link control / ZSW Vdc_ctrl
VECTOR_G
Can be changed: -
(Tech_ctrl)
Data type: Unsigned16
P-Group: Closed-loop control
Not for motor type: -
Min
-
Description:
Display and connector output for the status word of the DC link voltage control.
Bit field:
Bit
01
08
Note:
Re bit 01:
DC-link voltage control is disabled and enabled with p3513.
Re bit 08 = 1:
DC-link voltage control is selected using p3513.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Initialization
Fault
No ON command
Offset measurement running
ON delay active
Precharg. running
Operation
Signal name
DC link undervoltage alarm threshold
undershot
Signal name
Vdc-ctrl active
Vdc controller selected
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
6
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8932
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
FP
-
FP
-
-
567