Power Unit Sign-Of-Life Monitoring Tolerance Window / Pu Sol Monit Tol; Power Unit Sign-Of-Life Monitoring Fault Threshold; Component Trace Signal / Comp Trace Sig - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
When acknowledging a replacement, the "Generate report" function is automatically executed.
p7786.x is automatically set to 0 after POWER ON.
Bit field:
Bit
00
01
02
03
04
05
06
15
Notice:
This write process can take several minutes.
Note:
The power unit involved can be assigned the correct P index using p0124 (power unit detection via LED).
p7788

Power unit sign-of-life monitoring tolerance window / PU SoL monit tol

B_INF, VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
1
Description:
Setting of the tolerance window for the sign of life monitoring for communication to the power unit.
Note:
An active window is generated by means of DRIVE-CLiQ telegrams.
If more than one sign-of-life error appears in the window, then A30853 is output.
The lower the value in p7788, the greater the monitoring tolerance.
p7789
Power unit sign-of-life monitoring fault threshold / PU SoL monit F_thr
B_INF, VECTOR_G
Can be changed: U, T
Data type: Unsigned16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the number of consecutive sign-of-life errors that are tolerated for communication to the power unit.
Note:
F30008 is output in the case of a fault.
The higher the value in the parameter, the higher the monitoring tolerance.
p7790[0...15]

Component trace signal / Comp trace sig

B_INF, VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the individual signals for the component trace.
724
Signal name
Control Interface Module (CIM) replaced
Valve 1 replaced
Valve 2 replaced
Valve 3 replaced
Valve 4 replaced
Valve 5 replaced
Valve 6 replaced
Generate log
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1000
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1000
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
9
List Manual (LH2), 04/2014, A5E03263479A
0 signal
No
No
No
No
No
No
No
No
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
10
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
[0] 2
[1] 3
[2] 4
[3] 7
[4] 8
[5] 9
[6] 5
[7] 0
[8] 6
[9] 1
[10...15] 0
SINAMICS G130/G150