Co/Bo: Xist1_Erw Status / Xist1_Erw Stat; Bi: Xist1_Erw Reset Signal Source / Xist1_Erw Ress_Src - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r4654.0

CO/BO: XIST1_ERW status / XIST1_ERW stat

ENC
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Display and binector output to reset XIST1_ERW.
Bit field:
Bit
00
Dependency:
Refer to: p4652, r4653, p4655
Note:
The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
r4654.0...16
CO/BO: XIST1_ERW status / XIST1_ERW stat
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Display and binector output to reset XIST1_ERW.
Bit field:
Bit
00
08
16
Dependency:
Refer to: p4652, r4653, p4655
Note:
The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
p4655

BI: XIST1_ERW reset signal source / XIST1_ERW resS_src

ENC
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Sets the signal source to reset XIST1_ERW (CO: r4653).
Dependency:
Refer to: p4652, r4653, r4654
Note:
The reset of XIST1_ERW depends on the selected mode (p4652).
p4655[0...2]
BI: XIST1_ERW reset signal source / XIST1_ERW resS_src
VECTOR_G
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Sets the signal source to reset XIST1_ERW (CO: r4653).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
XIST1_ERW reset
Signal name
Encoder 1 XIST1_ERW reset
Encoder 2 XIST1_ERW reset
Encoder 3 XIST1_ERW reset
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
High
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
High
High
High
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Low
Low
Low
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4750
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
FP
-
-
-
643

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents