Number Of Motor Data Sets (Mds) / Mds Count; Motor Component Number / Mot Comp_No; Motor Configuration / Motor Config; Copy Motor Data Set Mds / Copy Mds - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p0130

Number of Motor Data Sets (MDS) / MDS count

VECTOR_G
Can be changed: C1(3)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
1
Description:
Sets the number of Motor Data Sets (MDS).
p0131[0...n]

Motor component number / Mot comp_no

VECTOR_G
Can be changed: C1(4)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
0
Description:
The motor data set is assigned to a motor using this parameter.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a motor.
p0133[0...n]

Motor configuration / Motor config

VECTOR_G
Can be changed: C2(1, 3)
Data type: Unsigned16
P-Group: Motor
Not for motor type: PEM, REL, FEM
Min
-
Description:
Configuration of the motor when commissioning the motor.
Bit field:
Bit
00
Dependency:
For standard induction motors (p0301 > 10000), bit 0 is automatically preassigned the connection type of the
selected data set.
For p0100 > 0 (60 Hz rated motor frequency), it is not possible to select bit 1.
Refer to: p0304, p0305
Note:
Re bit 00:
When changing the bits, the rated motor voltage p0304 and the rated motor current p0305 are automatically
converted to the selected connection type (star/delta).
For instance, this can be necessary if an 1LE1 motor is selected using the order number (MLFB) or code number
(p0300 = 100, p0301 = 1x0xx), and the motor connection type does not correspond to that of the data set.
p0139[0...2]

Copy Motor Data Set MDS / Copy MDS

VECTOR_G
Can be changed: C2(15)
Data type: Unsigned8
P-Group: Data sets
Not for motor type: -
Min
0
Description:
Copying a Motor Data Set (MDS) into another.
Index:
[0] = Source motor data set
[1] = Target motor data set
[2] = Start copying procedure
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Motor connection type
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
199
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
-
1 signal
Delta
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
31
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
Star
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents