Parameters For Data Sets; Parameters For Command Data Sets (Cds) - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters

2.3 Parameters for data sets

2.3
Parameters for data sets
2.3.1

Parameters for command data sets (CDS)

The following list contains the parameters that are dependent on the command data sets.
Product: SINAMICS G130/G150, Version: 4702900, Language: eng, Type: CDS
p0641[0...n]
p0700[0...n]
p0820[0...n]
p0821[0...n]
p0822[0...n]
p0823[0...n]
p0824[0...n]
p0828[0...n]
p0840[0...n]
p0844[0...n]
p0845[0...n]
p0848[0...n]
p0849[0...n]
p0852[0...n]
p0854[0...n]
p0855[0...n]
p0856[0...n]
p0858[0...n]
p1000[0...n]
p1020[0...n]
p1021[0...n]
p1022[0...n]
p1023[0...n]
p1035[0...n]
p1036[0...n]
p1039[0...n]
p1041[0...n]
p1042[0...n]
p1043[0...n]
p1044[0...n]
p1051[0...n]
p1052[0...n]
p1055[0...n]
p1056[0...n]
p1070[0...n]
p1071[0...n]
p1075[0...n]
p1076[0...n]
p1085[0...n]
p1088[0...n]
p1098[0...n]
p1106[0...n]
p1110[0...n]
p1111[0...n]
p1113[0...n]
p1122[0...n]
p1138[0...n]
1002
CI: Current limit variable / Curr lim var
Macro Binector Input (BI) / Macro BI
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
BI: Drive Data Set selection DDS bit 1 / DDS select., bit 1
BI: Drive Data Set selection DDS bit 2 / DDS select., bit 2
BI: Drive Data Set selection DDS bit 3 / DDS select., bit 3
BI: Drive Data Set selection DDS bit 4 / DDS select., bit 4
BI: Motor changeover feedback signal / Mot_chng fdbk sig
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 S_src 1
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 S_src 2
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 S_src 1
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 S_src 2
BI: Enable operation/inhibit operation / Operation enable
BI: Control by PLC/no control by PLC / Master ctrl by PLC
BI: Unconditionally release holding brake / Uncond open brake
BI: Speed controller enable / n_ctrl enable
BI: Unconditionally close holding brake / Uncond close brake
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
BI: Fixed speed setpoint selection Bit 2 / n_set_fixed Bit 2
BI: Fixed speed setpoint selection Bit 3 / n_set_fixed Bit 3
BI: Motorized potentiometer setpoint raise / Mop raise
BI: Motorized potentiometer lower setpoint / Mop lower
BI: Motorized potentiometer inversion / MotP inv
BI: Motorized potentiometer manual/automatic / Mop manual/auto
CI: Motorized potentiometer automatic setpoint / Mop auto setpoint
BI: Motorized potentiometer accept setting value / MotP acc set val
CI: Motorized potentiometer setting value / Mop set val
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
BI: Jog bit 0 / Jog bit 0
BI: Jog bit 1 / Jog bit 1
CI: Main setpoint / Main setpoint
CI: Main setpoint scaling / Main setp scal
CI: Supplementary setpoint / Suppl setp
CI: Supplementary setpoint scaling / Suppl setp scal
CI: Speed limit in positive direction of rotation / n_limit pos
CI: Speed limit in negative direction of rotation / n_limit neg
CI: Skip speed scaling / n_skip scal
CI: Minimum speed signal source / n_min s_src
BI: Inhibit negative direction / Inhib neg dir
BI: Inhibit positive direction / Inhib pos dir
BI: Setpoint inversion / Setp inv
BI: Bypass ramp-function generator / Bypass RFG
CI: Ramp-function generator ramp-up time scaling / RFG t_RU scal
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A