p1681[0...n]

Speed actual value filter 5 numerator damping / n_act_filt 5 D_n

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.000
Description:
Sets the numerator damping for speed actual value filter 5.
Dependency:
The speed actual value filter is activated via p1656.4 and parameterized via p1677 ... p1681.
p1699

Filter data acceptance / Filt data accept

VECTOR_G (n/M)
Can be changed: U, T
Data type: Integer16
P-Group: Closed-loop control
Not for motor type: REL
Min
0
Description:
Activates data acceptance for parameter changes for the filter.
p1699 = 0:
The new filter data are immediately accepted.
p1699 = 1:
The new filter data are only accepted when this parameter is reset.
Dependency:
Speed setpoint filter 1, 2 (p1414 and following)
Current setpoint filter 1 ... 4 (p1656 and following)
Current setpoint filter 5 ... 10 (function module, p5200 and following)
Refer to: p1656
p1702[0...n]

Isd current controller pre-control scaling / Isd_ctr_prectrScal

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, REL
Min
0.0 [%]
Description:
Sets the scaling of the dynamic current controller pre-control for the flux-generating current component Isd.
Note:
The parameter is effective for permanent and separately-excited synchronous motors.
p1703[0...n]

Isq current controller pre-control scaling / Isq_ctr_prectrScal

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.0 [%]
Description:
Sets the scaling of the dynamic current controller pre-control for the torque/force-generating current component Isq.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
10.000
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
200.0 [%]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
200.0 [%]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 4715
Unit selection: -
Expert list: 1
Factory setting
0.700
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: 6714
Unit selection: -
Expert list: 1
Factory setting
70.0 [%]
Access level: 4
Func. diagram: 6714
Unit selection: -
Expert list: 1
Factory setting
70.0 [%]
411