Ci: If2 Pzd Send Word / If2 Pzd Send Word - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p8851[0...24]

CI: IF2 PZD send word / IF2 PZD send word

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32 / Integer16
CU_G150_DP,
P-Group: Communications
CU_G150_PN
Not for motor type: -
Min
-
Description:
Selects the PZD (actual values) to be sent via interface 2 in the word format.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
[16] = PZD 17
[17] = PZD 18
[18] = PZD 19
[19] = PZD 20
[20] = PZD 21
[21] = PZD 22
[22] = PZD 23
[23] = PZD 24
[24] = PZD 25
Note:
IF2: Interface 2
p8851[0...11]
CI: IF2 PZD send word / IF2 PZD send word
ENC
Can be changed: U, T
Data type: Unsigned32 / Integer16
P-Group: Communications
Not for motor type: -
Min
-
Description:
Selects the PZD (actual values) to be sent via interface 2 in the word format.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
Dependency:
Refer to: p8861
Note:
IF2: Interface 2
792
Calculated: -
Dyn. index: -
Units group: -
Scaling: 4000H
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: 4000H
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 2493, 9210
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2487, 9208
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents