r0475

Gx_XIST1 coarse position safe most significant bit / Gx_XIST1 safe MSB

ENC
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Note:
MSB: Most Significant Bit
r0475[0...2]
Gx_XIST1 coarse position safe most significant bit / Gx_XIST1 safe MSB
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note:
MSB: Most Significant Bit
r0477

CO: Measuring gear position difference / Meas gear pos diff

ENC
Can be changed: -
Data type: Integer32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the position difference before the measuring gear between powering down and powering up.
Note:
The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
r0477[0...2]
CO: Measuring gear position difference / Meas gear pos diff
VECTOR_G
Can be changed: -
Data type: Integer32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the position difference before the measuring gear between powering down and powering up.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Note:
The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-