Co: Par_Circuit Phase Voltage Actual Value Phase W; Par_Circuit Gating Unit Status Word 1 / Gating Unit Zsw1; Par_Circuit Power Unit Rated Power / Pu P_Rated - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r7233[0...n]
CO: Par_circuit phase voltage actual value phase W / U_phase W act val
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the actual voltage, phase W.
The average value of all power units is displayed in r0089[2].
r7240[0...n]

Par_circuit gating unit status word 1 / Gating unit ZSW1

VECTOR_G (Parallel) Can be changed: -
Data type: Unsigned16
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays status word 1 of the power unit.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
r7250[0...4]

Par_circuit power unit rated power / PU P_rated

B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Converter
Not for motor type: -
Min
- [kW]
Description:
Displays the rated power of the individual power units connected in parallel for various load duty cycles.
The sum of the rated powers of all power units connected in parallel is displayed in r0206.
Index:
[0] = Rated value
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 cont duty cyc
[4] = S6 load duty cycle
Dependency:
The value is displayed in [kW] or [hp].
Refer to: p0100, p0205
714
Signal name
Fault time-critical
Gating unit mode bit 0
Pulse enable
Upper shutdown path
Lower shutdown path
Gating unit mode bit 1
Gating unit mode bit 2
Brake state
Brake diagnostics
Armature short-circuit braking
Gating unit state bit 0
Gating unit state bit 1
Gating unit state bit 2
Alarm status bit 0
Alarm status bit 1
Diagnostics 24 V
Calculated: -
Dyn. index: PDS, p0120
Units group: 5_3
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: PDS, p0120
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
ON
Inactive
Inactive
ON
ON
ON
ON
Active
ON
ON
ON
ON
ON
ON
Calculated: -
Dyn. index: -
Units group: 14_6
Scaling: -
Max
- [kW]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
OFF
OFF
OFF
Active
Active
OFF
OFF
OFF
OFF
Not active
OFF
OFF
OFF
OFF
OFF
OFF
Access level: 2
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [kW]
SINAMICS G130/G150
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents