Reset And Load All Parameters / Reset Load All Par; Save All Parameters / Save All Par - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p0976

Reset and load all parameters / Reset load all par

CU_G130_DP,
Can be changed: C1(30)
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Factory settings
CU_G150_PN
Not for motor type: -
Min
0
Description:
Resets or downloads all parameters of the drive system.
Value:
0:
1:
2:
3:
10:
11:
12:
20:
21:
22:
23:
24:
25:
26:
100:
1011: Start dnload of param. saved in volatile mem w/ p0977=1011
1012: Start dnload of param. saved in volatile mem w/ p0977=1012
1013: Start dnload of param. saved in volatile mem w/ p0977=1013
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
Note:
After all of the parameters have been reset to their factory setting, the system must be commissioned for the first time
again.
Resetting or loading is realized in the non-volatile memory.
Procedure:
1. Set p0009 = 30 (parameter reset).
2. Set p0976 to "required value". The system is rebooted.
p0976 is automatically set to 0 and p0009 is automatically set to 1 after this has been carried out.
p0977

Save all parameters / Save all par

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Factory settings
CU_G150_PN
Not for motor type: -
Min
0
Description:
Saves all parameters of the drive system to the non-volatile memory.
When saving, only the adjustable parameters intended to be saved are taken into account.
Value:
0:
1:
10:
11:
12:
20:
21:
22:
23:
24:
25:
26:
80:
280
Inactive
Start reset of all parameters to factory setting
Start dnload of param. saved in non-volatile mem w/ p0977=1
Start download of volatile parameters from RAM
Start dnload of param. saved in non-volatile mem w/ p0977=10
Start dnload of param. saved in non-volatile mem w/ p0977=11
Start dnload of param. saved in non-volatile mem w/ p0977=12
Start download Siemens internal setting 20
Start download Siemens internal setting 21
Start download Siemens internal setting 22
Start download Siemens internal setting 23
Start download Siemens internal setting 24
Start download Siemens internal setting 25
Start download Siemens internal setting 26
Start resetting of all BICO interconnections
Inactive
Save in non-volatile memory - downloaded at POWER ON
Save as opt. in non-vol. memory - downloaded w/ p0976=10
Save as opt. in non-vol. memory - downloaded w/ p0976=11
Save as opt. in non-vol. memory - downloaded w/ p0976=12
Save in non-volatile memory as setting 20 (reserved)
Save in non-volatile memory as setting 21 (reserved)
Save in non-volatile memory as setting 22 (reserved)
Save in non-volatile memory as setting 23 (reserved)
Save in non-volatile memory as setting 24 (reserved)
Save in non-volatile memory as setting 25 (reserved)
Save in non-volatile memory as setting 26 (reserved)
Save in non-volatile memory time-optimized (reserved)
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1013
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1013
List Manual (LH2), 04/2014, A5E03263479A
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150