Bi: Cu Signal Source For Terminal Di/Do 10 / Cu S_Src Di/Do 10; Bi: Cu Signal Source For Terminal Di/Do 11 / Cu S_Src Di/Do 11; Bi: Cu Signal Source For Terminal Di/Do 12 / Cu S_Src Di/Do 12; Bi: Cu Signal Source For Terminal Di/Do 13 / Cu S_Src Di/Do 13 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
Prerequisite: The DI/DO must be set as an output (p0728.9 = 1).
DI/DO: Bidirectional Digital Input/Output
p0740

BI: CU signal source for terminal DI/DO 10 / CU S_src DI/DO 10

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32 / Binary
CU_G150_DP,
P-Group: Commands
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 10 (X122.12 / X121.10).
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.10 = 1).
DI/DO: Bidirectional Digital Input/Output
p0741

BI: CU signal source for terminal DI/DO 11 / CU S_src DI/DO 11

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32 / Binary
CU_G150_DP,
P-Group: Commands
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 11 (X122.13 / X121.11).
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.11 = 1).
DI/DO: Bidirectional Digital Input/Output
p0742

BI: CU signal source for terminal DI/DO 12 / CU S_src DI/DO 12

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32 / Binary
CU_G150_DP,
P-Group: Commands
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 12 (X132.9 / X131.1).
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Prerequisite: The DI/DO must be set as an output (p0728.12 = 1).
DI/DO: Bidirectional Digital Input/Output
p0743

BI: CU signal source for terminal DI/DO 13 / CU S_src DI/DO 13

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned32 / Binary
CU_G150_DP,
P-Group: Commands
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the signal source for terminal DI/DO 13 (X132.10 / X131.2).
240
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 1
Func. diagram: 2131
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 2119, 2131
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 2119, 2132
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 2132
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150