Analog Sensor Input / Ana_Sens Inp; Analog Sensor Channel A Voltage At Actual Value Zero; Analog Sensor Channel A Voltage Per Encoder Period / Ana_Sens A U/Per - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p4671[0...n]

Analog sensor input / Ana_sens inp

ENC, VECTOR_G
Can be changed: C2(4)
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input circuit for the analog sensor.
Value:
0:
1:
2:
3:
Note:
p4671 = 0:
The two signals on a track are evaluated differentially.
p4671 = 1:
Only the non-inverted signal on a track is evaluated.
p4671 = 2:
Only the inverted signal on a track is evaluated.
p4671 = 3:
Only the non-inverted signal on a track (high resolution) is evaluated.
p4672[0...n]
Analog sensor channel A voltage at actual value zero / Ana_sens A U at 0
ENC, VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-10.0000 [V]
Description:
Sets the voltage when the connected sensor is at actual value zero.
At this voltage channel A supplies an actual value of zero.
p4673[0...n]

Analog sensor channel A voltage per encoder period / Ana_sens A U/per

ENC, VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-10.0000 [V]
Description:
Sets the output voltage range to be mapped for the connected analog sensor.
The voltage range is determined by the following parameters:
- p4672 (voltage at actual value 0)
- p4673 (voltage per encoder period)
Note:
The minimum actual value which can be mapped is equal to p4672 - p4673/2.
The maximum actual value which can be mapped is equal to p4672 + p4673/2.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Differential
Single-ended A, B
Single-ended A*, B*
Single-ended A, B sensitive
Calculated: -
Dyn. index: EDS, p0140
Units group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: EDS, p0140
Units group: -
Scaling: -
Max
10.0000 [V]
Calculated: -
Dyn. index: EDS, p0140
Units group: -
Scaling: -
Max
10.0000 [V]
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.0000 [V]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
6.0000 [V]
647

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents