Si Motion Gearbox Direction Of Rotation Reversal (Motor Module); Si Motion Encoder Comparison Algorithm (Motor Module); Si Motion Act Val Comparison Tol (Crosswise) (Motor Module) - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
p9339[0...7]
SI Motion gearbox direction of rotation reversal (Motor Module) / SI Mtn grbx rev MM
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the direction of rotation reversal for the gearbox.
0: No direction of rotation reversal
1: Direction of rotation reversal
The active gearbox stage can be switched over via PROFIsafe.
Index:
[0] = Gearbox 1
[1] = Gearbox 2
[2] = Gearbox 3
[3] = Gearbox 4
[4] = Gearbox 5
[5] = Gearbox 6
[6] = Gearbox 7
[7] = Gearbox 8
Dependency:
Refer to: p9321
p9341
SI Motion encoder comparison algorithm (Motor Module) / Enc comp algo MM
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the comparison algorithm for the encoder position monitoring functions.
The encoder that is used for the safe motion monitoring functions on the Motor Module/Hydraulic Module must be
parameterized in this parameter.
Value:
0:
10:
11:
12:
255:
Dependency:
Refer to: p9541
p9342
SI Motion act val comparison tol (crosswise) (Motor Module) / SI Mtn actV tol MM
VECTOR_G
Can be changed: C2(95)
Data type: FloatingPoint32
P-Group: Safety Integrated
Not for motor type: -
Min
0.0010 [mm]
Description:
Sets the tolerance for the crosswise data comparison of the actual position between the two monitoring channels.
For encoderless motion monitoring functions, the tolerance must be set to a higher value (12 degrees rotary, 1 mm
linear).
Dependency:
Refer to: p9542
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For a linear axis, the tolerance is internally limited to 10 mm.
For a "linear axis with rotating motor" and factory setting of p9320, p9321 and p9322, the factory setting of p9342
corresponds to a position tolerance of 36 ° on the motor side.
848
SMx20 safety algorithm
DQL binary safety algorithm
DQL linear non-binary safety algorithm
SMC30 safety algorithm
Safety algorithm unknown
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
255
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
360.0000 [mm]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
255
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.1000 [mm]
SINAMICS G130/G150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130