2 Parameters
2.2 List of parameters
06
07
Dependency:
Refer to: p3863
Warning:
It must be carefully ensured that the binector outputs BO: p3864.n are correctly interconnected and also that the
appropriate digital outputs are correctly connected up.
If the interconnection/connection is incorrect, in the case of an active DC link fast discharge, the software could
execute another function (incorrect function) via binector outputs BO: p3864.n or could also permanently control the
DC link fast discharge even if the line contactor is closed.
Note:
The DC link fast discharge is only possible for "booksize" formats. This function is not supported for "chassis"
formats.
p3865[0...7]

BI: Braking Module pre-warning I*t shutdown / BM I*t shutdown

B_INF (Brk Mod ext)
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the message "pre-alarm I*t shutdown" of the Braking Module.
BI: p3865[0...7] = 1 signal --> no pre-alarm, I*t shutdown
BI: p3865[0...7] = 0 signal --> pre-alarm I*t shutdown (A06901)
Note:
For the Braking Module, this message is output via the following terminal:
- X21.4 for the "Booksize" format
This function is not supported for the "chassis" format.
p3866[0...7]

BI: Braking Module fault / BM fault

B_INF (Brk Mod ext)
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the "Fault" message of the Braking Module.
BI: p3866[0...7] = 1 signal --> No fault
BI: p3866[0...7] = 0 signal --> fault (A06900)
For a 0 signal, an acknowledgement via BO: r3861 is automatically carried out at certain time intervals.
Note:
For the Braking Module, this message is output via the following terminal:
- X21.4 for the "Booksize" format
- X21.5 for the "Chassis" format
p3880

BI: ESM activation signal source / ESM act s s

VECTOR_G
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Functions
Not for motor type: -
Min
-
Description:
Sets the signal source to activate the essential service mode (ESM) via digital input.
Using this function, when required the motor can be operated for as long as possible (e.g. to extract smoke).
BI: p3880 = 1 signal:
The essential service mode is activated.
BI: p3880 = 0 signal:
The essential service mode is deactivated.
Dependency:
Refer to: p3881, p3882, p3883, p3886, r3887, p3888, r3889
590
Fast discharge Braking Module 7
Fast discharge Braking Module 8
High
High
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Low
Low
Access level: 3
Func. diagram: 9951
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 9951
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 7033
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents