r4694[0...19]
SMI spare part data backup motor order number / SMI dat_bkup MLFB
CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: Displays, signals
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the motor order number (MLFB) of the data backup selected with p4693.
Dependency:
Refer to: p4691, p4692
Caution:
If the selected subdirectory contains a number of data sets, "More Datasets" is displayed in r4694[0...19].
If there is no SMI data (motor/encoder data) in the selected subdirectory or if the selected subdirectory does not exist,
the following applies:
- The number of the next subdirectory located is displayed.
- This subdirectory is not checked for valid SMI data.
- If another subdirectory cannot be located, nothing is displayed in r4694[0...19].
Note:
SMI: SINAMICS Sensor Module Integrated
p4700[0...1]
Trace control / Trace control
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0
Description:
Setting to control the trace function.
Value:
0:
1:
Index:
[0] = Trace 0
[1] = Trace 1
p4701
Measuring function control / Meas fct ctrl
CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
0
Description:
Setting to control the measurement function.
Value:
0:
1:
2:
3:
p4703[0...1]
Trace options / Trace options
CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Trace and function generator
CU_G150_PN
Not for motor type: -
Min
-
Description:
Sets the options for the trace.
Index:
[0] = Trace 0
[1] = Trace 1
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Stop trace
Start trace
Stop measuring function
Start measuring function
Measuring function check parameterization
Start measuring function without enable signals
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
3
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0000 bin
655