Test Sockets Offset / Test Skt Offset; Test Socket Limit On/Off / Testsktlim On/Off; Test Socket Scaling Per Volt / Testsktscale/Volt - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

p0783[0...2]

Test sockets offset / Test skt offset

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Terminals
CU_G150_PN
Not for motor type: -
Min
-4.98 [V]
Description:
Sets an additional offset for the test sockets.
Index:
[0] = T0
[1] = T1
[2] = T2
p0784[0...2]

Test socket limit on/off / TestSktLim on/off

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Terminals
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the limit for a signal to be output via test sockets.
Value:
0:
1:
Index:
[0] = T0
[1] = T1
[2] = T2
Note:
Limiting on:
If signals are output outside the permissible measuring range, the signal is limited to 4.98 V or to 0 V.
Limiting off:
If signals are output outside the permissible measuring range, this causes signal overflow. In the case of signal
overflow, the signal jumps from 0 V to 4.98 V or from 4.98 V to 0 V.
r0786[0...2]

Test socket scaling per volt / TestSktScale/Volt

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: FloatingPoint32
CU_G150_DP,
P-Group: Terminals
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the scaling of the signal to be output.
A change in the output voltage by 1 volt corresponds to the value in this parameter. The units are determined by the
interconnected test signal.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Refer to: p0771, r0772, r0774, p0777, p0778, p0779, p0780, p0783, p0784
Note:
Example:
r0786[0] = 1500.0 and the measuring signal is r0063 (CO: Actual speed smoothed [rpm]).
A change of 1 V at the output of test socket T0 corresponds to 1500.0 [rpm].
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Limiting off
Limiting on
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
4.98 [V]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8134
Unit selection: -
Expert list: 1
Factory setting
0.00 [V]
Access level: 2
Func. diagram: 8134
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 8134
Unit selection: -
Expert list: 1
Factory setting
-
245

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: