Co/Bo: Ramp-Function Generator Status Word / Rfg Zsw; Flying Restart Operating Mode / Flyrest Op_Mode - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
06
11
13
14
15
r1199.0...8

CO/BO: Ramp-function generator status word / RFG ZSW

VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Setpoints
Not for motor type: -
Min
-
Description:
Displays the status word for the ramp-function generator (RFG).
Bit field:
Bit
00
01
02
03
04
05
06
07
08
Note:
Re bit 02:
The bit is the result of the OR logic operation - bit 00 and bit 01.
p1200[0...n]

Flying restart operating mode / FlyRest op_mode

VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Functions
Not for motor type: REL
Min
0
Description:
Sets the operating mode for flying restart.
The flying restart allows the drive converter to be powered up while the motor is still rotating. In so doing, the drive
converter output frequency is changed until the actual motor speed/velocity is found. The motor then accelerates up
to the setpoint at the ramp-function generator setting.
Value:
0:
1:
2:
3:
4:
5:
6:
Dependency:
For induction motors, the following applies:
A differentiation is made between flying restart for U/f control and for vector control (p1300).
Flying restart, U/f control: p1202, p1203, r1204
Flying restart, vector control: p1202, p1203, r1205
For synchronous motors, the following applies:
Flying restart is not possible with U/f control or if, in the case of sensorless vector control, a Voltage Sensing Module
(VSM) has not been connected and parameterized.
If two VSMs are connected to the Motor Module, then the motor voltage for the flying restart is measured using the
second VSM (see p0151[1]).
312
Inhibit positive direction
Setpoint inversion
Motorized potentiometer raise
Motorized potentiometer lower
Bypass ramp-function generator
Signal name
Ramp-up active
Ramp-down active
RFG active
Ramp-function generator set
Ramp-function generator held
Ramp-function generator tracking active
Maximum limit active
Ramp-function generator acceleration
positive
Ramp-function generator acceleration
negative
Flying restart inactive
Flying restart always active (start in setpoint direction)
FlyRestart active after on, fault, OFF2 (start in setp. dir.)
FlyRestart active after fault, OFF2 (start in setp. direction)
Flying restart always active (start only in setpoint direction)
FlyRestart active after on, fault, OFF2 (start only in setp_dir)
FlyRestart active after fault, OFF2 (start only in setp. dir.)
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
6
List Manual (LH2), 04/2014, A5E03263479A
No
No
No
No
No
Access level: 3
Func. diagram: 3001, 3080
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
Access level: 2
Func. diagram: 6300
Unit selection: -
Expert list: 1
Factory setting
0
SINAMICS G130/G150
3040
3040
3020
3020
3060,
3070
FP
-
-
-
-
-
-
-
-
-